流量校準(zhǔn)器Bios Defender 530-Low Flow    的詳細(xì)介紹流量校準(zhǔn)器Bios Defender 530-Low Flow 
Bios  Defender 530  Calibrator —— Coming January 2010
The Bios Defender 530,  with the ability to take both volumetric and standardized readings,  is the  latest addition to the popular Defender 510 and 520 line of Bios DryCal primary flow calibrators. Automatic correction of readings for temperature and pressure, rather than merely recording of ambient conditions, is essential for many applications. 
The Defender 530, like the other instruments in the line, provides users with a true primary flow calibrator for industrial hygiene, environmental and laboratory applications. The design offers low cost, light weight and ultra-compact size, incorporating the highly-regarded DryCal technology. It is small enough to fit easily into a slim briefcase for convenient transport.
Like all Bios calibrators, the Defender 530 is easy to use.  Turn it on. Connect it to a sampling pump. Start taking readings. It‘s as simple as that. Calibrations within a minute with no messy soap bubble solutions.
The Defender 510, 520 and 530 can take hands-free continuous readings while quickly and accurately setting the flow rate on air sampling pumps or other instruments. The Defender 510/520/530 calibrators connect to any PC and pre- and post-calibration data can be downloaded with the included Integrator 110 with the Optimizer Collect Light software. 
 
 
Bios Defender 530 Specifications
Size5.5"H x 6"W x 3"D
140 mm x 150 mm x 75 mm
Weight29 oz. / 820 g
Flow Ranges 
      DryCal Defender Low (L) Flow:5 to 500 ccm      DryCal  Defender Medium (M) Flow:50 - 5,000 ccm        DryCal Defender High (H) Flow:300 - 30,000 ccm
Accuracy 
      Volumetric±1.0%      Standardized±1.2%
User-Selectable Measurement Units      Volumetric FlowmL/min,  L/min, cc/min,  cf/min      Standarized FlowsmL/min, sL/min, scc/min, scf/min      PressuremmHg, PSI, kPa      TemperatureoC,  oF
Readings 
      Approximate Time per Reading1-15 seconds
      Reading StylesSingle (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements
Gas CompatibilityUse with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity
Flow ModesSuction or Pressure
Measurement Cell StyleIntegrated
Temperature & Pressure SensorsIn the flow stream
Press: 3.5 mmHg (typical), 7.0 mm (max)
Temp: 0.8 °C (typical) 1.3 °C (max)
Battery System 
      AC Adapter/Charger12 DC, > 250 ma, 2.5 mm, center positive
      Battery6V rechargeable, sealed lead-acid, 6-8 hours typical operation
      Battery Operational Time  (5 cycles/min), 3 hours backlight on, 8 hours backlight off
Pressure & Suction Fittings?” ID Hose Barb
DisplayBacklit graphical LCD
Storage Temperature0-70 °C
Ambient Humidity0-70% -  non-condensing
Operating Pressure  (Absolute)  15 PSI
WarrantyInstrument: 1 year, Battery: 6 months
Data Port 
Serial RS-232  (for use with Optimizer Collect software)
Data Cable1 meter (Defender Data Port to PC Serial Port)
Protective CaseSoft side or Pelican cases available
Laboratory AccreditationBacked by ISO 17025 accreditation by NVLAP of NIST
Instrument CertificationRoHS and CE Compliant
Bios Defender 500 Kits Include:  One flow c